Seitenansicht 33
Error Code
674
16
DBX 25
004
MMI file on the sys-
tem in not compatible
with the rest of the
base software
Push software from OLS Upgrade the base
software with cor-
rected base soft-
ware
DBX 27
000
The automatic or
manual date advance
interface has been set
with invalid parame-
ters (automatic: date
change time to mid-
night, or no working
day in the week;
Manual: day offset
exceeds limit).
Modify initialization of date
advance
DBX 27
003
Technical error Try with Service
PSD Order a new
PSD
DBX 29
002
this message appear
for system with con-
nected inserter. Mes-
sage Id not in
dictionary
Check connection between inserter and base
DBX 32
000
The system didn't
receive the length
value from dynamic
scale
Ask customer to check
dynamic scale wiring
1 Check connection
2 Check dynamic
scale board
3 Check length sen-
sor
DBX 32
001
The system didn't
receive the length
value from the inserter
Check connection bet-
ween inserter and base
Check connection
and parameters
DBX 32
002
The system didn't
receive the thickness
value from inserter
Check connection bet-
ween inserter and base
Check the inserter
connection and
parameters
DBX 32
003
The system didn't
receive the thickness
value from the dyna-
mic scale
Ask customer to check
dynamic scale wiring
1 Check connection
2 Check dynamic
scale board
3 Check thickness
sensor
DBX 32
004
The system didn't
receive the oversize
status from the dyna-
mic scale
Ask customer to check
dynamic scale wiring
1 Check connection
2 Check dynamic
scale board
3 Check oversize
sensor
Code Description Helpdesk On site