Dbx 20 Series Betriebsanweisung Seite 53

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 62
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 52
Error Code
693
16
DWA 01
007
the "dynamic scale
oversize"sensor is
masked during weig-
hing phase
Ask customer to try with
change on selection on
feeder
1 Check gap bet-
ween envelope is
enough - most pro-
bably an envelope
is in the oversize
sensor area
If not, the sensor is
damaged and need
some repair
DWA 01
008
the "Zero weight"of the
dynamic scale is out of
valid measure (+/-0.2g
TBC)
1 Take out the envelope on the dynamic scale
2 Check if nothing disturb it (fan, envelope resi-
due, weak table, somebody is leaning on it, etc..)
then press on OK key to clear the error
DWA 01
009
the "dynamic scale
entry" sensor is activa-
ted when the batch
starts
1 Take out the envelope
2 Press on OK key to clear the error
If it is still occurring, may be the sensor needs to
be replaced
DWA 01
010
the dynamic scale
"oversize" sensor is
activated when the
batch starts
1 Take out the envelope
2 Press on OK key to clear the error if it is still
occurring, may be the sensor is activated by some
light around the machine ( lamp, sun, etc..): ask
to check , Take out , hide etc..
Iif it is still occurring, may be the sensor needs to
be replaced:
DWA 02
000
the Dynamic scale
detects a weight of
more than +/- 400gr
during the initialization
1 Take out the envelope
2 Power Off, then On the machine (or unplug)
If it is still occurring, may be the dynamic scale
needs to be recalibrated or the load cell to be
replaced:
DWA 02
001
the base board, load
cell or cabling in bet-
ween is most probably
damaged
1 Ask the customer to
power Off, then On the
machine (or unplug)
2 If it fails again, then pre-
pare a tech visit to replace
the Dynamic Scale main
board, cable or the load
cell
Replace the Dyna-
mic Scale main
board, cable or the
load cell
DWA 02
002
the Dynamic scale
analog / digital conver-
ter detects an error
during the initialization
1 Ask the customer to
power Off, then On the
machine (or unplug)
2 If it fails, then prepare a
tech visit to replace the
Dynamic Scale main board
Replace the Dyna-
mic Scale main
board
Code Description Helpdesk On site
Seitenansicht 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 61 62

Kommentare zu diesen Handbüchern

Keine Kommentare